• Japanese
  • Chinese

Engine Intake System

Category:relating to "Engine Intake System"

  • Proprietary & Special Technologies

* Click on the menu to see the category listHow to use this function

This system supplies air to engines at a constant temperature and humidity during an engine unit test.

Specifications

Temperature range 15 to 30°C ± 0.5°C
Humidity range 55%RH ± 5%RH
Supply air flow 400 to 1,200 m3/h
Dimensions 2,100 mm (W) x 16,000 mm (L) x 1,950 mm (D)

Features

  • Control accuracy of ±0.5°C
  • Non-stop and single-step operation in flexible response to cooling loads in the range of 0 to 100%
  • Cooling and re-heating with the high-temperature refrigerant at the outlet of the compressor as a heating source.
    Higher COP than the cooled-water type (annual power consumption reduced 30%)
  • Compact type integrating a freezer, HVAC, and control panel